by ColC » Tue Nov 19, 2013 7:19 pm
The error is that it is using the wrong target height so if I had zero height it may have used height of 1.6(m) And it does not appear to affect the traverse heights while you keep a clear head. The error appears when setting the backsight, the wrong height difference appears.
This has only just started to happen to me. Although I think it happened for a short while previously. I suspect it occurred when I changed backsights by just changing the point backsight number and not fully re-shooting the backsight. I have tried system reset on my Surveyor+ without success, but I think I will have to re-install SurvCe as I suspect there is a corrupted file somewhere.
What is a give away is that it is retaining a HR which is not necessarily from the recent station target heights. It reappears despite me checking all entry points and entering new values. And it may recall a height from a previous job.
I am a bit old fashion in that I still use a TS and it probably doesn't affect many other users.